MBX OPC Server Suite
Compliance-Certified OPC Server Suite for Modicon Networks and Devices
The all-in-one MBX OPC Server Suite includes Cyberlogic OPC server and all device drivers for
all Modicon networks, PLCs and interface cards.
The suite includes:
- Cyberlogic OPC Server.
- MBX Driver for all Modicon Modbus Plus network adapters.
- MBX Gateway Driver for remote access to all Modicon networks.
- Ethernet MBX Driver for Modbus TCP/IP communications.
- Serial MBX Driver for Modbus communications.
- Virtual MBX Driver for enabling 16-bit legacy applications in 32-bit Windows.
OPC Server Features
The Only Choice For Mission-Critical Applications
The MBX OPC Server Suite has integrated fault-tolerant communication features not found in other
OPC servers. Multiple, priority-based access paths can be used to build a true redundant communication
architecture below the server level. The built-in Health Watchdog monitors the health of all network
connections to all physical devices. The auto-switching access paths can be configured to quickly
redirect communications to an unlimited number of plant-floor devices and networks.
Built for Performance
The MBX OPC server guarantees minimal load on the communication networks through advanced message
transaction optimizers. In addition to server-level global optimization, the high-performance server
also offers unsolicited data updates with advanced message filtering from unwanted data sources to
ensure data integrity and security.
Packed with Intelligent and Powerful Features
Using Auto-configuration and DirectAccess™ features, a user can configure a minimal server
setup with a single mouse click and gain access to all the registers in each network node without
any user configuration. Power users can control many aspects of the server configuration. For enhanced
security, write operations can be disabled for some or all of the data sources at data item, folder,
device, device folder or network node levels. DirectAccess writes can also be disabled at each network
node.
In version 7, DirectAccess feature supports redundancy. This allows all DirectAccess operations
to switch seamlessly between redundant network nodes.
Includes All required Device Drivers
The MBX OPC Server Suite includes the MBX Driver Suite, the worldwide standard for communication
drivers for Modbus, Modbus Plus and Modbus/TCP networks.
MBX OPC Server Suite Features
Configuration
- Network node automatic configuration
- Logical grouping of tags within a single PLC
- Logical organization of tags across multiple PLCs
- Configuration import and export
- Configuration import from third-party OPC servers
Redundancy
- Network and device level redundancy
- Unlimited number of backup PLC data sources
- Unlimited number of backup networks
- Automatic switchover to higher priority data path
Data Features
- Data write protection
- Data conversion
- Span messages/force atomic r/w for large data types
- Default canonical data type override
- 64-bit data support
- Arrays
- Bit arrays
- Bit fields
- Bit order reconfiguration
Data Types
- 1-bit Boolean
- Signed 8-bit integer
- Unsigned 8-bit integer
- Signed 16-bit integer
- Unsigned 16-bit integer
- Signed 32-bit integer
- Unsigned 32-bit integer
- Signed 64-bit integer
- Unsigned 64-bit integer
- IEEE format 32-bit floating point number
- IEEE format 64-bit floating point number
- BCD value in the range of 0 - 9999
- BCD value in the range of 0 - 99999999
- Zero terminated ASCII string of 8-bit characters
- Zero terminated UNICODE string of 16-bit characters
- Multiple bit field
Communications
- Unsolicited communications
- Filtering of unsolicited message sources (no priority)
- Filtering of unsolicited message sources (with priority)
- DirectAccess™ to all PLC registers
- Load Balancing to prevent network overload
- Load Balancing to prevent PLC overload
Troubleshooting & Reliability
- OPC Server Status diagnostic utility
- Cyberlogic Control Panel configuration utility
- Diagnostic Status Tags built into OPC Server
- Windows Performance Monitor support built into device drivers
- Windows Event Logger support built into device drivers
- Windows Event Logger support built into OPC Server
- Health Monitor for all network nodes
Product Details
Product Help Files
MBX OPC Server Suite Components
- Cyberlogic OPC Server
- MBX Driver
- MBX Gateway
- Ethernet MBX Driver
- Serial MBX Driver
- Virtual MBX Driver
OPC Specifications
- Data Access 3.0
- Data Access 2.05a
- Data Access 1.0a
- Alarms & Events 1.1
- XML Data Access 1.0
OPC DA Driver Agent supports
- Data Access 3.0
- Data Access 2.05a
- Data Access 1.0a
Networks
- Modicon Modbus Plus
- Modicon Ethernet (Modbus over TCP/IP)
- Modicon Serial Modbus/RTU
- Modicon Serial Modbus/ASCII
- MBX Gateway for Remote Access
PLCs
- Modicon 184 family
- Modicon 384 family
- Modicon 484 family
- Modicon 584 family
- Modicon 884 family
- Modicon 984 family
- Modicon Micro 84
- Modicon Modcell
- Modicon Quantum family
- Modicon Momentum family
- Modicon Premium family
- Modicon M340
- Any Modbus-compatible device
Kernel Mode Device Drivers
- Modicon SA-85-00
- Modicon SA-85-02 (Dual Channel)
- Modicon SM-85
- Modicon AT-984-AT0
- Modicon AT-984-AT2
- Modicon AT-984-AT4
- Modicon MC-984
- Modicon Atrium
- Modicon PCI-85 (416NHM30030)
- Modicon PCI-85 (416NHM30032) (Dual Channel)
- Modicon PCMCIA (416NHM21200) (Type II)
- Modicon PCMCIA (416NHM21203) (Type III)
- Modicon PCMCIA (416NHM21234) (Type III PnP)
- Modicon TSXCUSBMBP Rev 1 (USB - Modbus Plus Adapter)
- Modicon TSXCUSBMBP Rev 2 (USB - Modbus Plus Adapter)
Download Free Trial